SUT00S11007-30 Daikin Hybrid Super Unit System Single Pump Inverter Hydraulic Unit

Delivery: Options Available

For any enquiry or technical support,
please contact us on 0116 478 4200

Contact Us
Part Number: SUT00S11007-30

This super unit incorporates the multi-stage pressure/flow rate control system as well as the functions of conventional hydraulic units, which results in use of a reduced number of valves.

 

The high-efficiency IPM motor drive system that utilise the Daikin original air conditioning motor and inverter technologies provides a high energy-saving ratio of up to 50%

 

Four or sixteen pressure (P) - flow rate (Q) setting patterns are available for cylinder control

 

Reduced shock during flow rate or pressure changes

 

Low noise level of 60dB (A) and the noise level of 73dB (A) or less even in full-operation areas.

 

Multi-stage P-Q remote control by communication (Function: -C)

 

The Super Unit and main machine can be remotely controlled with the same panel. This function eliminates complicated individual operations and installation space limitations. 

Maximum flow rate (L/min) 110
Maximum operating pressure (MPa) 7.0
Operating flow rate adjustment range (L/min) 13.3 to 110
Operating pressure adjustment range (MPa) 1.5 to 7.0
Motor Capacity 11.0kW
Power Supply 3-phase, 200V/50Hz, 200V/60Hz, 200V/60Hz
Rated Current (A) 38.3 (200V/50Hz), 37.8 (200V/60Hz), 34.9 (220/60Hz)
Main Power Supply Breaker Setting 75A
External Input Signal 5 Channels
External Output Signal 2 Digital, 1 Contact
Tank Capacity Tankless
Weight 112kg
Hydraulic Oil Dedicated mineral hydraulic oil/wear-resistant hydraulic oil
Viscosity Grade ISO VG32 to 68
Viscosity Range 15 to 400 mm2/s
Pollution Degree NAS10 or lower
Operating Hydraulic Oil Temperature 0 to 60°C (recommended range 15 to 50°C)
Operating Ambient Temperature 0 to 40°C
Storage Ambient Temperature -20 to 60°C
Operating Ambient Humidity 85% RH Max (No Condensation)